Power Distribution Components for AI Data Centers
Source qualified power distribution components for high-density AI and HPC data center infrastructure. Rack PDU, intelligent PDU, busway, busbar, high-current connectors, cable assemblies, and power monitoring.
Components for High-Density Data Center Power Infrastructure
AI data centers operate at rack power densities of 30–100+ kW, requiring power distribution infrastructure engineered for high current, high availability, and intelligent monitoring. We source qualified components across the full power distribution chain — from facility-level busway and busbar systems to rack PDU, high-current connectors, cable assemblies, and power monitoring devices.
Rack PDU
Basic and metered rack power distribution units for standard and high-density data center racks. Single-phase and three-phase configurations.
Key Specifications
| Input Voltage | Single-phase 120V/208V/240V; three-phase 208V/400V/415V |
| Input Current | 16A, 20A, 30A, 32A, 63A — model dependent |
| Outlet Types | C13, C19, NEMA 5-15/5-20, IEC 60309, custom |
| Outlet Count | 8 to 48 outlets — model dependent |
| Form Factor | 0U vertical, 1U horizontal, 2U horizontal |
| Monitoring | None (basic), inlet metering, outlet metering |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- Standard density rack power distribution
- Edge and colocation data centers
- Server rack power feeds
- UPS output distribution
Have a specific requirement for Rack PDU? Submit your specification or BOM for a sourcing review.
Request QuoteIntelligent Rack PDU
Per-outlet metered and switched intelligent rack PDUs with remote monitoring, outlet-level control, and DCIM integration for AI data center power management.
Key Specifications
| Input Voltage | Single-phase 208V/240V; three-phase 208V/400V/415V |
| Input Current | 16A to 63A — model dependent |
| Metering | Per-outlet current, voltage, power (W), energy (kWh) |
| Switching | Per-outlet on/off switching — model dependent |
| Communication | Ethernet (SNMP, Modbus TCP, REST API, DCIM) |
| Environmental | Optional temperature/humidity sensor port |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- AI data center rack power management
- Remote outlet switching and reboot
- Per-outlet power metering and logging
- DCIM and BMS integration
Have a specific requirement for Intelligent Rack PDU? Submit your specification or BOM for a sourcing review.
Request QuoteBusway Systems
Overhead and underfloor busway systems for flexible, high-current power distribution in AI data center aisles. Tap-off units enable reconfigurable rack power feeds.
Key Specifications
| Current Rating | 100A to 1600A — model dependent |
| Voltage | 400V/415V three-phase; 208V three-phase |
| Tap-off Units | 16A to 125A; C13/C19/IEC 60309/custom outlets |
| IP Rating | IP40, IP54, IP65 — model dependent |
| Conductor | Copper or aluminum; sandwich or open construction |
| Standards | IEC 61439-6, UL 857 — confirm by model |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- AI data center aisle power distribution
- High-density rack power feeds
- Flexible and reconfigurable power infrastructure
- Overhead and underfloor distribution
Have a specific requirement for Busway Systems? Submit your specification or BOM for a sourcing review.
Request QuoteBusbar Systems
Copper and aluminum busbar systems for switchgear, PDU, and power panel assemblies in data center power infrastructure.
Key Specifications
| Materials | Copper (ETP, OFC), aluminum alloy 1350/6101 |
| Current Rating | Calculated by cross-section and installation — consult engineer |
| Insulation | Bare, heat-shrink sleeved, epoxy-coated, PVC-coated |
| Cross-sections | Custom cut and drilled to drawing |
| Plating | Tin-plated, silver-plated, bare — specify application |
| Standards | IEC 60068, BS EN 13601 — confirm by specification |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- Switchgear and MCC assemblies
- PDU internal power distribution
- Power panel and distribution board assemblies
- High-current connection between equipment
Have a specific requirement for Busbar Systems? Submit your specification or BOM for a sourcing review.
Request QuoteHigh-Current Connectors
High-current and high-voltage connectors for data center power infrastructure including IEC 60309 industrial connectors, cam-lock connectors, and custom power connectors.
Key Specifications
| Types | IEC 60309 (CEE), cam-lock, Anderson, custom |
| Current Rating | 16A to 800A — type dependent |
| Voltage Rating | Up to 1000V AC/DC — type dependent |
| IP Rating | IP44, IP67, IP68 — type dependent |
| Body Materials | Nylon, polycarbonate, aluminum, stainless steel |
| Standards | IEC 60309, UL 1682, custom — specify application |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- Temporary and permanent power connections
- Generator and UPS connections
- PDU input and output connections
- High-current cable assembly terminations
Have a specific requirement for High-Current Connectors? Submit your specification or BOM for a sourcing review.
Request QuotePower Cable Assemblies
Custom power cable assemblies for data center power distribution including whips, jumpers, and branch circuit assemblies with specified connectors and cable specifications.
Key Specifications
| Cable Types | THHN, SOOW, SJT, MC cable, armored — specify application |
| Conductor Sizes | AWG 14 to 4/0; 10mm² to 240mm² |
| Connector Types | IEC 60309, NEMA, cam-lock, custom — specify ends |
| Voltage Rating | 300V to 1000V — cable and connector dependent |
| Current Rating | Per NEC/IEC ampacity tables — specify conductor and installation |
| Testing | Hi-pot, continuity, polarity — available on request |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- PDU input whips and jumpers
- Rack-to-rack power connections
- Generator and UPS output connections
- Branch circuit assemblies
Have a specific requirement for Power Cable Assemblies? Submit your specification or BOM for a sourcing review.
Request QuotePower Distribution Modules
Rack-mount and chassis-mount power distribution modules for server and storage platform power distribution, including OCP and custom form factors.
Key Specifications
| Form Factors | OCP, custom chassis-mount, rack-mount |
| Input | Three-phase 208V/400V; single-phase 208V/240V |
| Output | Multiple branch circuits with overcurrent protection |
| Monitoring | Optional per-branch metering and communication |
| Protection | MCB, fuse, or electronic overcurrent protection |
| Customization | Custom outlet configuration, monitoring, and form factor |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- OCP server platform power distribution
- Custom server chassis power distribution
- Storage platform power distribution
- High-density blade server power
Have a specific requirement for Power Distribution Modules? Submit your specification or BOM for a sourcing review.
Request QuoteCircuit Protection
Miniature circuit breakers (MCB), molded case circuit breakers (MCCB), fuses, and surge protection devices for data center power distribution assemblies.
Key Specifications
| Types | MCB, MCCB, fuse, SPD, RCBO |
| Current Rating | 1A to 1600A — type dependent |
| Voltage Rating | Up to 1000V AC/DC — type dependent |
| Breaking Capacity | 6kA to 150kA — specify fault level |
| Tripping Characteristics | B, C, D curves (MCB); adjustable (MCCB) |
| Standards | IEC 60898, IEC 60947, UL 489 — confirm by model |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- PDU branch circuit protection
- Switchgear and distribution board protection
- Server and storage platform protection
- Surge protection for sensitive equipment
Have a specific requirement for Circuit Protection? Submit your specification or BOM for a sourcing review.
Request QuotePower Monitoring
Power meters, energy analyzers, and power quality monitors for data center power infrastructure monitoring and DCIM integration.
Key Specifications
| Measurement | V, A, W, VA, VAR, PF, kWh, harmonics |
| Accuracy | Class 0.2S to Class 1 — specify application |
| Communication | Modbus RTU/TCP, BACnet, SNMP, Ethernet |
| Display | Local LCD, remote HMI, none — model dependent |
| Installation | DIN rail, panel-mount, inline — model dependent |
| Standards | IEC 62053, ANSI C12 — confirm by model |
Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.
Typical Applications
- Facility-level power metering
- PDU and switchgear power monitoring
- PUE measurement and reporting
- DCIM and BMS integration
Have a specific requirement for Power Monitoring? Submit your specification or BOM for a sourcing review.
Request QuoteSource Power Distribution Components for Your Data Center Project
Submit your BOM or specification for a sourcing review. We work with qualified manufacturers to source power distribution components for AI data center, HPC, and colocation projects.