Power Distribution

Power Distribution Components for AI Data Centers

Source qualified power distribution components for high-density AI and HPC data center infrastructure. Rack PDU, intelligent PDU, busway, busbar, high-current connectors, cable assemblies, and power monitoring.

Components for High-Density Data Center Power Infrastructure

AI data centers operate at rack power densities of 30–100+ kW, requiring power distribution infrastructure engineered for high current, high availability, and intelligent monitoring. We source qualified components across the full power distribution chain — from facility-level busway and busbar systems to rack PDU, high-current connectors, cable assemblies, and power monitoring devices.

01

Rack PDU

Basic and metered rack power distribution units for standard and high-density data center racks. Single-phase and three-phase configurations.

Rack PDUPower StripC13C19Single-phaseThree-phase

Key Specifications

Input VoltageSingle-phase 120V/208V/240V; three-phase 208V/400V/415V
Input Current16A, 20A, 30A, 32A, 63A — model dependent
Outlet TypesC13, C19, NEMA 5-15/5-20, IEC 60309, custom
Outlet Count8 to 48 outlets — model dependent
Form Factor0U vertical, 1U horizontal, 2U horizontal
MonitoringNone (basic), inlet metering, outlet metering

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Standard density rack power distribution
  • Edge and colocation data centers
  • Server rack power feeds
  • UPS output distribution

Have a specific requirement for Rack PDU? Submit your specification or BOM for a sourcing review.

Request Quote
02

Intelligent Rack PDU

Per-outlet metered and switched intelligent rack PDUs with remote monitoring, outlet-level control, and DCIM integration for AI data center power management.

Intelligent PDUMetered PDUSwitched PDUSNMPDCIMPer-outlet metering

Key Specifications

Input VoltageSingle-phase 208V/240V; three-phase 208V/400V/415V
Input Current16A to 63A — model dependent
MeteringPer-outlet current, voltage, power (W), energy (kWh)
SwitchingPer-outlet on/off switching — model dependent
CommunicationEthernet (SNMP, Modbus TCP, REST API, DCIM)
EnvironmentalOptional temperature/humidity sensor port

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • AI data center rack power management
  • Remote outlet switching and reboot
  • Per-outlet power metering and logging
  • DCIM and BMS integration

Have a specific requirement for Intelligent Rack PDU? Submit your specification or BOM for a sourcing review.

Request Quote
03

Busway Systems

Overhead and underfloor busway systems for flexible, high-current power distribution in AI data center aisles. Tap-off units enable reconfigurable rack power feeds.

BuswayBusductTap-offOverhead buswayHigh-currentFlexible PDU

Key Specifications

Current Rating100A to 1600A — model dependent
Voltage400V/415V three-phase; 208V three-phase
Tap-off Units16A to 125A; C13/C19/IEC 60309/custom outlets
IP RatingIP40, IP54, IP65 — model dependent
ConductorCopper or aluminum; sandwich or open construction
StandardsIEC 61439-6, UL 857 — confirm by model

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • AI data center aisle power distribution
  • High-density rack power feeds
  • Flexible and reconfigurable power infrastructure
  • Overhead and underfloor distribution

Have a specific requirement for Busway Systems? Submit your specification or BOM for a sourcing review.

Request Quote
04

Busbar Systems

Copper and aluminum busbar systems for switchgear, PDU, and power panel assemblies in data center power infrastructure.

BusbarCopper busbarAluminum busbarSwitchgearPDU assemblyHigh-current

Key Specifications

MaterialsCopper (ETP, OFC), aluminum alloy 1350/6101
Current RatingCalculated by cross-section and installation — consult engineer
InsulationBare, heat-shrink sleeved, epoxy-coated, PVC-coated
Cross-sectionsCustom cut and drilled to drawing
PlatingTin-plated, silver-plated, bare — specify application
StandardsIEC 60068, BS EN 13601 — confirm by specification

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Switchgear and MCC assemblies
  • PDU internal power distribution
  • Power panel and distribution board assemblies
  • High-current connection between equipment

Have a specific requirement for Busbar Systems? Submit your specification or BOM for a sourcing review.

Request Quote
05

High-Current Connectors

High-current and high-voltage connectors for data center power infrastructure including IEC 60309 industrial connectors, cam-lock connectors, and custom power connectors.

IEC 60309Cam-lockHigh-current connectorCEE connectorPower connectorAnderson connector

Key Specifications

TypesIEC 60309 (CEE), cam-lock, Anderson, custom
Current Rating16A to 800A — type dependent
Voltage RatingUp to 1000V AC/DC — type dependent
IP RatingIP44, IP67, IP68 — type dependent
Body MaterialsNylon, polycarbonate, aluminum, stainless steel
StandardsIEC 60309, UL 1682, custom — specify application

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Temporary and permanent power connections
  • Generator and UPS connections
  • PDU input and output connections
  • High-current cable assembly terminations

Have a specific requirement for High-Current Connectors? Submit your specification or BOM for a sourcing review.

Request Quote
06

Power Cable Assemblies

Custom power cable assemblies for data center power distribution including whips, jumpers, and branch circuit assemblies with specified connectors and cable specifications.

Power cable assemblyWhipJumperBranch circuitCustom cablePDU whip

Key Specifications

Cable TypesTHHN, SOOW, SJT, MC cable, armored — specify application
Conductor SizesAWG 14 to 4/0; 10mm² to 240mm²
Connector TypesIEC 60309, NEMA, cam-lock, custom — specify ends
Voltage Rating300V to 1000V — cable and connector dependent
Current RatingPer NEC/IEC ampacity tables — specify conductor and installation
TestingHi-pot, continuity, polarity — available on request

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • PDU input whips and jumpers
  • Rack-to-rack power connections
  • Generator and UPS output connections
  • Branch circuit assemblies

Have a specific requirement for Power Cable Assemblies? Submit your specification or BOM for a sourcing review.

Request Quote
07

Power Distribution Modules

Rack-mount and chassis-mount power distribution modules for server and storage platform power distribution, including OCP and custom form factors.

PDMPower distribution moduleOCPChassis powerBranch circuitCustom PDU

Key Specifications

Form FactorsOCP, custom chassis-mount, rack-mount
InputThree-phase 208V/400V; single-phase 208V/240V
OutputMultiple branch circuits with overcurrent protection
MonitoringOptional per-branch metering and communication
ProtectionMCB, fuse, or electronic overcurrent protection
CustomizationCustom outlet configuration, monitoring, and form factor

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • OCP server platform power distribution
  • Custom server chassis power distribution
  • Storage platform power distribution
  • High-density blade server power

Have a specific requirement for Power Distribution Modules? Submit your specification or BOM for a sourcing review.

Request Quote
08

Circuit Protection

Miniature circuit breakers (MCB), molded case circuit breakers (MCCB), fuses, and surge protection devices for data center power distribution assemblies.

MCBMCCBCircuit breakerFuseSPDSurge protectionRCBO

Key Specifications

TypesMCB, MCCB, fuse, SPD, RCBO
Current Rating1A to 1600A — type dependent
Voltage RatingUp to 1000V AC/DC — type dependent
Breaking Capacity6kA to 150kA — specify fault level
Tripping CharacteristicsB, C, D curves (MCB); adjustable (MCCB)
StandardsIEC 60898, IEC 60947, UL 489 — confirm by model

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • PDU branch circuit protection
  • Switchgear and distribution board protection
  • Server and storage platform protection
  • Surge protection for sensitive equipment

Have a specific requirement for Circuit Protection? Submit your specification or BOM for a sourcing review.

Request Quote
09

Power Monitoring

Power meters, energy analyzers, and power quality monitors for data center power infrastructure monitoring and DCIM integration.

Power meterEnergy meterPower qualityPUEModbusDCIM integration

Key Specifications

MeasurementV, A, W, VA, VAR, PF, kWh, harmonics
AccuracyClass 0.2S to Class 1 — specify application
CommunicationModbus RTU/TCP, BACnet, SNMP, Ethernet
DisplayLocal LCD, remote HMI, none — model dependent
InstallationDIN rail, panel-mount, inline — model dependent
StandardsIEC 62053, ANSI C12 — confirm by model

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Facility-level power metering
  • PDU and switchgear power monitoring
  • PUE measurement and reporting
  • DCIM and BMS integration

Have a specific requirement for Power Monitoring? Submit your specification or BOM for a sourcing review.

Request Quote

Source Power Distribution Components for Your Data Center Project

Submit your BOM or specification for a sourcing review. We work with qualified manufacturers to source power distribution components for AI data center, HPC, and colocation projects.