Technical Resources

AI Data Center Technical Resources

Engineering guides for AI data center liquid cooling, rack power distribution and infrastructure component selection.

Liquid Cooling12 min read

What Is Direct-to-Chip Liquid Cooling for AI Data Centers?

Covers the complete direct-to-chip cooling loop architecture: CDU, manifold, hose assemblies, QDC couplings, cold plates, coolant flow, monitoring, and leak detection. Includes a component architecture diagram and procurement considerations.

CDUManifoldQDCCold platesLeak detection
Read Guide
Selection Guide8 min read

How to Select QDCs for Data Center Liquid Cooling

Engineering selection guide for quick disconnect couplings. Covers connection size, flow requirement, pressure drop, coolant compatibility, seal materials, dry-break vs wet-break, mating cycles, and integration with hose, manifold, and cold plate.

Flow ratePressure ratingSeal materialsDry-breakMating cycles
Read Guide
Selection Guide10 min read

Cold Plate Selection Guide for AI Servers and GPUs

Selection guide for cold plates in AI server and GPU direct-to-chip cooling. Covers processor type, thermal load, flow requirement, pressure drop, geometry, materials, channel architecture, and QDC integration.

GPU / CPUThermal loadChannel architectureMaterialsCustom design
Read Guide
Power Distribution10 min read

AI Data Center Rack Power Density Explained

Explains why AI rack power density is increasing and the infrastructure implications. Covers rack PDU, busway, busbar, high-current connectors, cable assemblies, and power monitoring for high-density AI deployments.

Rack PDUBuswayHigh-currentPower monitoringRedundancy
Read Guide
Selection Guide9 min read

How to Select a Rack PDU for High-Density AI Data Centers

Selection guide for rack PDUs in high-density AI data center deployments. Covers input configuration, outlet requirements, metering levels, redundancy, busway integration, and a complete selection checklist.

Input ratingOutlet typesMeteringRedundancyBusway integration
Read Guide
Technical Comparison8 min read

Busway vs Cable for Data Center Power Distribution

Objective comparison of overhead busway and cable assemblies for data center power distribution. Covers architecture, installation, scalability, rack changes, space considerations, maintenance, and high-density AI rack deployment factors.

BuswayCable assembliesScalabilityHigh-densityComparison
Read Guide